Jump to a detailed breakdown

These are the sections of the rule with full section-by-section modification detail — covering plan review, new construction/remodel commissioning, Certificate of Occupancy, annual inspections, hood/balloon/light tests, sprinkler/standpipe/hydrant flow testing, PIVs, and fire alarm work. Everything else is covered in the Full Index below.

Other adopted subjects

Separate Safety Fire Commissioner rules that Rule 120-3-3 cross-references (e.g. NFPA 30 & the flammable-liquids family) — integrated directly here instead of linking out to rules.sos.ga.gov.

Explicitly NOT adopted

These sections of the model codes are deleted or expressly declared "not adopted" by Georgia — meaning your local jurisdiction's own rules govern instead, not the base IFC/NFPA text.

All 182 adopted codes & standards

Sortable, searchable index of every code/standard adopted under Rule 120-3-3-.04. No mod = adopted as published, no Georgia changes. Modified = click the row for a one-line summary of what changed. Detail here = click the row to jump straight to the full breakdown in this site. 120-3-XX = not modified in 120-3-3 at all — the rule just points to a different Safety Fire Commissioner subject; click the row to open that subject directly. Cross-ref = special applicability note rather than a redline.

ItemStandardEditionStatus

Editions currently adopted by Georgia

The three base codes referenced throughout this site, and who actually adopts each one — they're not all the same authority or the same adoption cycle.

CodeEditionAdopted byEffective
IFCInternational Fire Code, 2024 ed. (with Georgia modifications)Safety Fire Commissioner — Rule 120-3-3Current
IBCInternational Building Code, 2024 ed. (with Georgia Amendments)Dept. of Community Affairs (DCA)Jan 1, 2026
LSCNFPA 101 Life Safety Code, 2024 ed. (with Georgia modifications)Safety Fire Commissioner — Rule 120-3-3Current

IBC is adopted separately by DCA, not the Safety Fire Commissioner — it isn't part of Rule 120-3-3 itself, but IFC and the Life Safety Code both reference it constantly (construction types, occupancy classification, plan review), so it's included here for that reason.

Keeping this current

This is a snapshot, not a live feed — Georgia's rules site doesn't support the kind of automated polling that would let this update itself. Just ask for a refresh any time you suspect something changed; based on the amendment history below, checking in every couple of months (or before a task-book submission or plan review that hinges on a specific section) is plenty.

Edition currency: the edition shown in the index above is whatever Georgia has formally adopted by rule — that's what's enforceable here, even after NFPA publishes something newer. A newer NFPA edition existing doesn't change what applies in Georgia until this rule is amended to cite it.
Georgia's amendment history (Rule 120-3-3)
Dec 8, 2025Amended, eff. Dec 28, 2025
Sept 12, 2025Amended, eff. Oct 2, 2025
June 25, 2025Amended, eff. July 15, 2025
May 7, 2025Amended, eff. May 27, 2025
Apr 11, 2025Amended, eff. May 1, 2025
Site update history — what's changed here, and when